Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13695340
- Product Categories
- Keshi Da UPS power supply
- Hills UPS power supply
- Branch UPS power supply
- APC UPS power supply
- Matsushita Battery
- Yuasa Battery
- Germany sunshine battery
- Dorset Battery
- Friendly Links
Information Name: | Yuasa emergency batteries, Yuasa NP38-12 price |
Published: | 2015-05-25 |
Validity: | 600 |
Specifications: | 12V38AH |
Quantity: | 1000.00 |
Price Description: | |
Detailed Product Description: | Yuasa emergency batteries, Yuasa Yuasa Battery NP38-12 NP38-12 price information on this site is: http: //www.cntrades.com/tradeinfo/chanpin_detail_3057363.html Yuasa Battery NP Series: NP100-12.NP65- 12 NP38-12.NP24-12.NP7-12 Yuasa Battery NPL series: NPL100-12.NPL65-12 NPL38-12.NP24-12.NP7L-12 Guangdong Yuasa Battery 1, long life design grid with anti-growth structure, can withstand severe electrochemical reaction is highly resistant to corrosion of lead-calcium alloy grid, ensure UXH battery float life of up to 10 years. 2, high energy density and comparison with similar products, UXH battery energy density (wh / l, wh / kg) increased by about 15%, and thus discharge into more sustained, high-rate discharge performance better. 3, security UXH cells use highly secure terminal structure, eliminating the need for terminal or pool shell leakage concerns, be sure to use the process of security and efficiency. 4, maintenance-free, without replenishment. 5, the valve automatically Kai together to maintain normal pressure within the battery. 6, no surplus electrolyte can be placed horizontally. 7, constant voltage charging under (2.275V / single cell) situation, without a balanced charge. 8, UXH100-12, UXH200-6 comes with explosion-proof devices, more perfect security. Guangdong Yuasa Battery 1, gas is generated inside the rechargeable battery and simple maintenance is absorbed substantially reduced to the electrolyte, basically no electrolyte decreased. 2, holding a liquid electrolyte is absorbed in a high specific separator, the flow state is not maintained, even if the fall can also be used. (Down more than 90 degrees can not be used) 3, superior safety performance due to extreme overcharge operation errors caused by too much gas can be released to prevent rupture of the battery. 4, minimal self-discharge with a special lead-calcium alloy production grid, the self-discharge to a minimum. 5, long life (design life of 3 to 5 years) the economy is good battery grid using good corrosion resistance special lead-calcium alloy, while using special separators can keep the electrolyte, and then pressed at the same time with a strong positive plate active material, to prevent the loss, it is a long life, economical battery. 6, the internal resistance due to the resistance of small, high-current discharge characteristics. 7, after the excellent deep discharge recovery capabilities in case of long discharge, as long as the full charge does not appear substantially reduced capacity, the new lead-acid batteries can be restored quickly after the addition of electrolyte, temperature is the reason? Join the new battery electrolyte temperature rise and internal factors a new battery. After dry-charged battery fluid temperature rise increases the battery temperature is not very clear, it is because dry charged plates through anti-oxidation treatment, the factory battery in a fully charged state, you can use the load after dosing; ordinary plate battery, without the antioxidant treatment, negative plates in half fully charged state, a considerable portion of the material is lead oxide and sulfuric acid reaction to produce a lot of heat, so long high temperature. Sometimes the summer temperature reaches above 50 ℃, the charge should pay attention to artificial cooling. Constant pressure limiting manner VRLA battery charge, how to determine the battery is fully charged? There are two basis: 1) charging time of 18 to 24 hours (not the depth of discharge can be shorter, such as 20% depth of discharge the battery, the charging time can be shortened to 10 hours). 2) the charge current is reduced to the minimum 3 hours and continuous change. Produce plates sulfated What are the reasons.? Sulfated produce plates for the following reasons: 1) Initial battery charging less than the initial charge or a longer break time; 2) battery charging less than the long-term; 3) failure to charge and discharge; 4) regularly overcharge or low current deep discharge; 5) electrolyte density is too high or the temperature is too high, the formation of lead sulfate depth difficult to restore; 6) the battery holds a longer time, long-term use without periodic charging; 7) electrolyte impurities, large self-discharge; 8 ) local effects of an internal short circuit or battery drain surface water caused more; 9) inside the battery electrolyte level is low, so that the exposed part of the plate sulfation. |
Admin>>>
You are the 20436 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Jin Yi Jia Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 20436 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Jin Yi Jia Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility